Measuring the fibre’s acceptance cone
Connect total internal reflection to numerical aperture, then calculate the cone angle from a measured light spot.
Aim & apparatus
Estimate the numerical aperture (NA) of an optical fibre from the spot diameter at known screen distances, and determine its acceptance half-angle in air.
The physical apparatus comprises a suitable light source, a straight fibre, a perpendicular screen or NA jig, and a scale. Measure d from the fibre’s output face, not from the source or a mounting bracket.
Guiding light by total internal reflection
In the step-index ray model, the core index n₁ exceeds the cladding index n₂. A ray striking the core–cladding boundary from the core is totally internally reflected when its incidence angle exceeds θc. This angle is measured from the boundary normal.
Snell’s law at the limiting boundary gives sin θc = n₂/n₁. At the entrance face, Snell’s law connects the external entry angle to the ray direction inside the core. Combining the two relations gives the acceptance condition for guided meridional rays.
The acceptance angle θa is measured outside the fibre from its axis, whereas θc is measured inside from an interface normal. Confusing these two angles gives the wrong interpretation of NA.
Deriving the screen formula
For a short straight fibre with a suitable mode-filling launch, the output cone can be used to estimate the input acceptance cone. Let the spot radius be r = D/2 and the axial screen distance be d.
From the right triangle, tan θa = r/d. The hypotenuse is √(r² + d²), so sin θa = r/√(r² + d²). In air, n₀ ≈ 1, giving the measurement formula.
This geometric estimate is most meaningful when the output cone is fully populated and its edge is measured consistently. A restricted launch or diffraction-dominated single-mode pattern needs a more careful interpretation.
Taking measurements
- Set the screen distance d and note the length unit.
- Move the two caliper jaws to opposite spot boundaries using the same edge criterion each time. The measured diameter is the absolute difference of the jaw positions.
- Record D and calculate NA with D and d in the same units. Calculate θa in degrees if reporting an angle.
- Repeat for several screen distances. For a fixed physical output cone, D is proportional to d and NA should stay approximately constant.
- Compare the estimates and discuss the spread rather than assuming every rounded value is exact.
Worked example & units
If d = 15.0 mm and D = 16.0 mm, NA = 16/√(4 × 15² + 16²) = 16/34 ≈ 0.4706. The acceptance half-angle is sin⁻¹(0.4706) ≈ 28.07°.
The full cone angle is twice the half-angle, about 56.14° in this example. NA itself has no unit.
A millimetre-to-metre conversion is unnecessary if both measured lengths already use millimetres. Do not mix a radius in one calculation with a diameter in another.
Precautions & model limits
Keep the screen perpendicular to the axis and avoid tight bends. Clean the fibre ends and avoid looking into a source or illuminated fibre. Ambient light and fuzzy spot edges increase reading uncertainty.
This workspace calculates NA from the chosen jaw separation and screen distance; its drawn spot follows those controls. It is a geometry and calculation exercise, not an independent measurement of a fixed calibrated fibre.
A larger NA accepts a wider range of entry directions, but it does not by itself guarantee lower attenuation or better bandwidth. Multimode dispersion and launch conditions also matter.