Measuring wavelengths with a grating
Align the spectrometer, read the same spectral line on both sides, and use diffraction geometry to calculate its wavelength.
Aim & apparatus
Determine spectral wavelengths using a plane transmission grating of known spacing d and measured diffraction angles.
The collimator forms a parallel beam from a narrow slit. A level grating table holds the grating, and a telescope with crosswires locates each spectral image. Opposite verniers help reduce eccentricity errors in the angular scale.
Why a grating separates colours
Each opening diffracts light. Waves from neighbouring openings have an angle-dependent path difference, and principal maxima occur where the contributions from many openings reinforce one another.
At normal incidence, the path difference between adjacent slits is d sin θ. Setting it equal to an integer multiple of wavelength gives the grating equation. Longer wavelengths appear at larger absolute angles in a given order.
At zero order, all wavelengths overlap. Higher orders are allowed only when |mλ/d| ≤ 1, and real slit envelopes and instrument geometry may further limit their visibility.
Alignment & angular readings
Focus the eyepiece on its crosswires, the telescope for parallel light, and the collimator so the slit produces a parallel beam. Set the grating for normal incidence before applying the simplified equation.
In this simulator the normal-incidence grating setting is 90°. The direct telescope direction is the reference. Read the same colour and diffraction order on both sides of that direction.
For symmetric first-order images, correct the angular separation for 0°/360° wrap-around and divide by two to get θ. Analyse corresponding differences from each vernier before averaging; do not average raw wrap-around angles.
Taking measurements
- Keep the grating at its normal-incidence setting. Adjust the telescope to bring a spectral line onto the crosswire.
- Choose a colour and record its first-order angular readings on one side, then find that same colour on the other side.
- Use the lock and fine-angle controls to settle each reading without changing alignment.
- Correct angular wrap-around, calculate θ, and apply λ = d sin θ for the table’s first-order calculation.
- Repeat for other visible lines and compare calculated wavelengths. The stopwatch is a convenience, not part of the wavelength equation.
Worked example & units
For 15,000 lines per inch, d = 0.0254/15000 m ≈ 1.6933 × 10⁻⁶ m. First-order images at about +20.36° and −20.36° give θ ≈ 20.36°, so λ ≈ 589 nm. This is an illustrative angle calculation, not a saved reading.
Convert the line density before calculating spacing. For lines per millimetre, d in metres is 10⁻³ divided by that density. Convert degrees to radians if using a calculator or programming function that expects radians.
Angular dispersion is dθ/dλ = m/(d cos θ). Ideal resolving power is λ/Δλ = mN, where N is the total number of illuminated rulings, not the number per unit length.
Precautions & model limits
Keep the slit narrow but visible, level the table, and maintain normal incidence. Read the same line and order on both sides. Do not touch or scratch the grating surface.
The simulator permits rotation away from normal incidence, but the observation table’s simplified first-order formula assumes normal incidence. Arbitrary grating settings should not be used with that calculation.
A prism’s minimum-deviation formula does not apply here. This lab uses diffraction and interference, whereas a prism separates colours by wavelength-dependent refraction.